NO LOAD & LOAD TEST BENCH

NO LOAD & LOAD TEST BENCH: These are the test benches incorporating control & measurement circuitry necessary for testing single phase as well as three phase transformers of several VA to MVA rating & voltage class of 11KV/433V,as well 33KV/11 KV, after manufacturing, repairing, reconditioning.

SKU: d0e11387e6ff Category:

Description

Test Sets For Transformer

NO LOAD & LOAD TEST BENCH

These are the test benches incorporating control & measurement circuitry necessary for testing single phase as well as three phase transformers of several VA to MVA rating & voltage class of 11KV/433V,as well 33KV/11 KV, after manufacturing, repairing, reconditioning.

Product Overview

Following tests can be done by these Test Sets. No load Test from L.T. side Input voltage to L.T.

Technical Specifications

Type Input — Output — Range of transformers under test
LDNLD1P1 230V, 50Hz. , single phase AC. — 0-240V AC at 50A 0-480V AC at 25A 0-960V AC at 12.5A — Distribution transformers from 3KVA to 250KVA i.e. 20KV primary & 480V secondary.
LDNLD3P1 415V, 3phase, 4 wire, 50Hz. AC. — 0 to 500V, 3 phase continuously variable AC. Capacity: 28A. — Distribution & Power transformers upto 500KVA.
LDNLD3P2 400V, 3 phase, 4 wire, 50Hz. AC. — 3 phase output: 0-2.75KV AC 0-5.5KV AC 0-11KV AC Capacity: 200KVA. 1phase output: 0-500V AC; Capacity: 2.5KVA. — 3 phase transformers- Upto 33KV (Ph-Ph) primary voltage & Upto 11KV secondary voltage. Capacity: 3MVA Max. 1 phase transformers- Upto 11KV primary voltage & 250V secondary voltage. Capacity: 50KVA Max.

Features and Details

  • No load Test from L.T. side Input voltage to L.T. side. No load current. No load or excitation loss.
  • Load Test Impedance voltage. Rated L.T. & H.T. current. Conductor loss
  • Temperature rise Test Injection only at equivalent short circuit current (Temperature/Time measurement scheme is available at extra cost).
  • Polarity
  • Phase sequence
  • Ratio error
  • Foot switch interlock.
  • Zero start interlock.
  • Over load and short circuit.
  • A remote interlock connector to interlock the test cage area.

Selection Considerations

When evaluating NO LOAD & LOAD TEST BENCH, consider the intended application, required operating parameters, capacity or measurement range, installation conditions, accessories and documentation relevant to your project. Confirm product-specific requirements and configuration with Interlabs before procurement.

About Interlabs

Interlabs, associated with International Biological Laboratories, supplies scientific, laboratory, educational and engineering equipment from India. The company identifies its history as dating to 1958. Contact Interlabs to confirm product details and supporting documentation for your requirement.

Request Product Information

Share your application and technical requirements for NO LOAD & LOAD TEST BENCH to discuss suitability, available configurations and a quotation.

Request a Quote

Frequently Asked Questions

What is NO LOAD & LOAD TEST BENCH used for?

These are the test benches incorporating control & measurement circuitry necessary for testing single phase as well as three phase transformers of several VA to MVA rating & voltage class of 11KV/433V,as well 33KV/11 KV, after manufacturing, repairing, reconditioning.

What should I confirm before ordering NO LOAD & LOAD TEST BENCH?

Confirm the intended application, technical specifications, available configuration, accessories, documentation and delivery requirements with Interlabs.